Product
ProductCurrent position > Product detail

Acetylene flowmeter

『Acetylene flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

There are several types of acetylene pressure gauges: single-stage, two-stage, and pressure gauges with flow meters. The single-stage pressure reducing gauge has a relatively simple structure with only one pressure reducing chamber device, which can reduce the pressure of high-pressure acetylene gas to the required working pressure at once. Its characteristic is low cost, but the stability of pressure reduction is slightly poor, and the output pressure is relatively affected by changes in input pressure and brightness force.

2. The two-stage pressure reducing gauge is equipped with a two-stage pressure reducing device, and the gas first undergoes a first stage rough pressure reduction, and then passes through a second stage fine pressure reduction. Its core advantage is the ability to provide a more stable output pressure, which is less affected by input pressure fluctuations, making it more suitable for welding or cutting applications that require high pressure stability. 3. The pressure reducing gauge with flow meter integrates flow measurement function on the basic pressure reducing function, which can intuitively display the real-time usage flow of acetylene gas. This feature makes it widely used in the work of accurately controlling gas consumption based on the required chain width, making it easy for users to grasp and manage gas consumption.

2. Technical parameters of gas flowmeter

Technical parameters of gas flowmeter are as follows

1. Measurement range: Under standard conditions (20 ℃, 101.33KPa), the measurable gas flow range is (0.05-80) Nm/s

2. Applicable medium: Suitable for measuring most clean gases except acetylene gas

3. Temperature adaptability: The ambient tem

Acetylene flowmeter
perature is between -40 ℃ and+60 ℃, and the medium temperature can withstand -10 ℃ to+200 ℃

4. Accuracy and repeatability: The reading accuracy reaches ± 1%, and the repeatability at full range is ± 0.5%

5. Output signal: Provides instantaneous flow 4-20mA DC signal, maximum load of 600 Ω, supports RS232 and RS485 communication differential mode, response speed less than 1 second

6. Power supply requirement: 24VDC power supply, voltage fluctuation range of ± 10%

7. Mechanical connection: adopts 3/4 NPT Stainless steel fasteners, standard probe length is 800mm, can be customized for special requirements

8. Straight pipe section requirements: There are no strict regulations on the length of straight pipe sections, which can be selected according to actual installation needs. 9. Pressure loss: The pressure loss generated by the flowmeter during operation can be ignored. 10. Working pressure

1.6MPa is the maximum working pressure that the flowmeter can withstand. 11. Display function: The on-site display adopts LED, with the upper row displaying instantaneous flow rate with 4 characters per line, and the lower row displaying cumulative flow rate, supporting switching between imperial or metric units. 12. Data protection: Accumulated traffic data is stored in EEROM, which can be saved for hundreds of years even in the event of a power outage. 13. Material selection: The sensor and pipeline body are made of 316L material, or alternatively, Hastelloy C. 14. Protection level: With IP65 protection, suitable for use in various harsh environments. 15. Transmission unit: Provides explosion-proof packaging options to ensure safe use in hazardous areas. Extended Data Gas Flow Meter is an instrument

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610